Liquid Flow Pro 17

  • Get the Wotofo Flow Pro Replacement Coil - 5 Pack at factory prices from VaporBeast. Find bulk Wotofo Flow coils with free shipping!
  • Enhanced Liquid & Gas Flow Computer for ControlLogix® MVI56E-AFC. ProSoft Technology’s MVI56E-AFC in-chassis flow computer solution allows you to combine the power and scalability of a ControlLogix® automation system with the functionality typically only seen in a stand-alone flow computers or dedicated measurement RTU’s.
  • 'We dance for laughter,we dance for tears,we dance for madness,we dance for fears,we dance for hopes,we dance for screams,we are the dancers,we create the dreams.'
  1. Flow Pro Blowers
  2. Liquid Flow Pro 17 3
  3. Liquid Flow Pro 17 Download
  4. Flow Pro Water Filters

MVI56E-AFC

Buy Liquid Plumr Pro-Strength Clog Destroyer Foaming Clog Fighter (17 fl oz) online and have it delivered to your door in as fast as 1 hour. Your first Delivery is free. Try it today! Do not use with a plunger, in toilets or with ammonia, toilet bowl cleaners, or non-Liquid-Plumr clog removers (to avoid hazardous gas). Liquid-Plumr contains biodegradable surfactants and no phosphorous. Excessive heat or cold may cause some ingredients in Liquid-Plumr to form clumps, but this should not affect its performance.

ProSoft Technology’s MVI56E-AFC in-chassis flow computer solution allows you to combine the power and scalability of a ControlLogix® automation system with the functionality typically only seen in a stand-alone flow computers or dedicated measurement RTU’s. This provides you with the industry standard calculations, archiving, and reporting needed for custody transfer and allocation based measurement functions for Oil and Gas operations.

Flow Pro Blowers

By combining automation and measurement functions into a single solution, this helps to reduce overall support and integration costs for Oil and Gas applications while also decreasing your overall capital spend. This simplified solution allows you to optimize your resources.

In addition, because our flow computer sits in a ControlLogix system, you can take advantage of Rockwell Automation’s distributed I/O capability, wide range of communications protocols, and ProSoft’s wireless radios to greatly reduce wiring to your transmitters and I/O devices.

Since the module operates as a co-processor for measurement related functions to the ControlLogix system, and as measurement requirements of the site grow, you can simply add an additional MVI56E-AFC module to increase your measurement capabilities to an individual site. A truly scalable automation and measurement solution.

Flow

Architectures

Features and Benefits

  • Meter runs: The module can calculate up to 16 meter runs with four streams per run simultaneously, making it cost-effective, since more meters can be connected to a single flow computer.
  • Modbus capabilities: Remote configuration and diagnostics via Ethernet (Modbus® TCP/IP). Flexible serial port configurations allow for either two Modbus slave ports or one Modbus slave and one Modbus Master port. All data, including configuration, calculated results, and historical archives, are available using either the Modbus TCP/IP server or Modbus slave serial ports.
  • Customized Modbus Data Mapping: Remapping to a virtual slave enables data concentration, reducing bandwidth load on the communication system.
  • Auditability: Our configuration software provides the ability to download and view archives and events. Audit Scan captures process inputs and calculated results as 'snapshots”, allowing verification of calculations. The Event Log records significant events and alarms. Hourly and daily archives are configurable historical records of user-selected data. The data can be viewed online, printed, or saved to a file in .txt or .csv format. Archive data can be exported to Flow-Cal .cfx format. Meter calibration and verification are stored on the module.
  • Meter proving: Allows for meter proving with 3 configurable prover types.
  • Security: Password protection schemes are available to control user access and log meter calibration and verification activities. A built-in web server allows local/remote configuration, monitoring, and wireless network diagnostics.

Configuration

The EAFC Manager is a free Windows 7-based configuration, reporting, and monitoring tool provided with all MVIxxE-AFC modules. Project configurations may be uploaded, downloaded, and saved to the PC under user-selectable file names.

Specifications

General Specifications

  • The module is recognized by the processor as an Input/Output module.
  • The included Add-On Instruction (AOI) files are used for data transfers between the module and processor, reducing configuration time.
  • Configuration is downloaded over Ethernet by way of the Modbus TCP/IP servers, or delivered by user-defined ladder.

Functional Specifications

The MVI56E-AFC operates as a powerful flow computer module, augmenting the operation of the ControlLogix processor by providing a dedicated and accurate set of flow calculations.

  • Calculates flow rates, accumulated volumes, accumulated mass, and (for gas product) accumulated energy.
  • Calculation results are transferred to processor memory and may also be transferred to a SCADA host using Modbus serial or Modbus TCP/IP.
  • User-configurable, allowing each of the meter runs to be individually set up to meet the specific requirements of an application.

Archiving

  • Supports data archiving and event logging.
  • Data archiving is available for each meter run, as two separately configurable files, one called “hourly” and the other called “daily”, whose records are intended to implement the Quantity Transaction Records (QTRs) required by applicable measurement standards. Under default configuration:
    • (a) Records are written once each hour to the “hourly” file and once each day to the “daily” file, with additional records written to both files upon occurrence of an event that could affect measurement results (such as the change in value of a significant parameter).
    • (b) Each record consists of 100 registers formatted with up to 50 data point values selected as being appropriate for the meter’s configuration (type, product, etc.) and compliant with QTR requirements.
    • (c) Each file is formatted for a few of the most recent records to be kept in higher-speed local storage plus 1440 more records in larger-capacity, slower “extended” storage.
  • Logging feature provides storage of up to 2,000 events and separately 2000 alarms.

Configurable Options

  • User-selectable units for totalizers and flow rates on a per-channel basis.
  • Roll-over value for resettable and non-resettable totalizers for every meter channel.
  • Process analog input units and ranges (pressure, temperature, differential pressure, density) from analog input modules and pulse inputs from pulse/frequency input modules in a ControlLogix chassis.
  • Fluid selection provides a choice of several liquid groups or gas measurement, using AGA, API, and/or ISO calculations.
  • Event log reports for all security-sensitive configuration data (for example, orifice diameter) are date- and time-stamped. This data can be saved to disk for importing into any spreadsheet or printed as a hard copy.

Modbus Interface

  • SCADA communication is provided by the Modbus TCP/IP server and Modbus slave serial ports.
  • Modbus table may be re-mapped as a virtual Modbus slave for user-assigned contiguous register polling by a SCADA client/master (up to 20,000 registers).
  • Poll remote devices (such as a Gas Chromatograph) by utilizing the Modbus Master serial port.
  • Alarm, event, and meter archive log files may be downloaded in Enron Modbus format.

System Requirements -EAFC Manager

This configuration software is designed for Microsoft Windows 7. Minimum hardware requirements for a Windows 7 system are as listed below. More advanced operating systems have significantly higher minimum requirements regardless of EAFC Manager minimum requirements.

  • 1 GHz or faster 32-bit (x86) or 64-bit (x64) processor
  • 1 GB RAM (32-bit) or 2 GB RAM (64-bit)
  • 16 GB available hard drive space (32-bit) or 20GB (64-bit)
  • Assigned IP Address

Hardware

Specification

Description

Backplane Current Load

800 mA @ 5 Vdc
3 mA @ 24 Vdc

Operating Temperature

32°F to 140°F (0°C to 60°C)

Storage Temperature

-40°F to 185°F (-40°C to 85°C)

Shock

Vibration

30g operational, 50g non-operational

5g from 10 Hz to 150 Hz

Relative Humidity

5% to 95% RH, with no condensation

LED Indicators

Module Status, Backplane Transfer Status,
Application Status, Serial Activity

Ethernet port

1 Ethernet Application Port

10/100 Mbps, RJ45
Link and Activity LED
Auto crossover (Auto MDIX)

Serial Application Ports (P1 & P2)

2 Serial Application Ports

RJ45 (DB-9M with supplied cable)
RS-232, RS-485, RS-422 jumper selectable
RS-232 handshaking configurable
500V optical isolation from backplane
Full hardware handshaking control, providing radio, modem and multi-drop support

Shipped with Unit

(2) RJ45 to DB-9M cables
(1) 6-foot DB-9F to DB-9F null modem cable

Downloads

MVI56E-AFC Datasheet343.05 kBLast Modified 11/06/2019
MVI56-AFC vs MVI56E-AFC Comparison27.20 kBLast Modified 11/06/2019
MVI56E-AFC FAQ Sheet325.83 kBLast Modified 11/06/2019
MVI56E-AFC AddOn Instructions406.54 kBLast Modified 11/06/2019
MVIxxE-AFC Reference Guide7.70 MBLast Modified 11/06/2019
MVI56E-AFC Release Notes576.03 kBLast Modified 11/06/2019
MVIxxE-AFC Setup and Configuration Guide6.26 MBLast Modified 11/06/2019
MVIxxE-AFC AER Directive 017811.23 kBLast Modified 11/06/2019
MVI56E-AFC Installer Certification Requirements1.58 MBLast Modified 11/06/2019
ProSoft EAFC Export Utility - User Manual2.26 MBLast Modified 11/06/2019
ProSoft EAFC Manager
Technical Note - MVI56E-AFC or MVI69E-AFC - How to Fetch Archives295.17 kBLast Modified 10/02/2019
Technical Note - Updating MVI56E-AFC Network Configuration using API902.47 kBLast Modified 11/07/2019

Videos

Liquid Flow Pro 17

Liquid Flow Pro 17 3

Setting up your ProSoft Flow Computer for ControlLogix

Liquid Flow Pro 17 Download

Certifications

Flow Pro Water Filters

Ex Certificate (ATEX Directive) 140.03 kBLast Modified 02/26/2020
CB Safety 340.34 kBLast Modified 02/26/2020
DNV GL 218.23 kBLast Modified 05/25/2016
Declaration of Conformity (RoHS/CE) 299.08 kBLast Modified 08/14/2018
UL/cUL; Class 1, Div. 2 1.20 MBLast Modified 02/28/2020